Kataria Engineering

Slump Test of Fresh Concrete — Lab Manual

Slump Test of Fresh Concrete: objective, apparatus, step-by-step procedure, formulas, typical values and a printable data sheet (ASTM C143 / BS EN 12350-2).

Objective & standard

Workability of fresh concrete at the site, before placing.

Standard: ASTM C143 / BS EN 12350-2

Apparatus

  • Slump cone 300 mm high (200/100 mm dia.)
  • Tamping rod 16 mm × 600 mm
  • Base plate, scale

Procedure

  1. Dampen the cone and plate; hold the cone down with the foot rests.
  2. Fill in 3 equal layers, rodding each 25 times through its depth.
  3. Strike off the top; lift the cone straight up in 5 ± 2 seconds.
  4. Measure the drop from the cone top to the highest point of the concrete.
  5. Record the type: true, shear or collapse (repeat a shear slump).

Calculations

  • Slump = 300 mm − height of slumped concrete

Typical values: Footings & slabs 50–100 mm, beams/columns 75–125 mm, pumped concrete 100–150 mm.

Open the Slump Test calculator →

Data sheet (print this page)

Project: ____________________   Sample: __________   Date: __________   Tested by: __________

Truck / batchTimeSlump (mm)TypeRemarks
     
     
     
     
     
     