CBR → Mr & k-value

Convert CBR to resilient modulus (AASHTO 1993 and MEPDG) and modulus of subgrade reaction k, and get CBR from a DCP test.

Loading the calculator… (JavaScript is needed)

About this test

Enter a soaked CBR — or a DCP penetration index — to get Mr for flexible pavements and the k-value for rigid pavements, rafts and slab-on-grade models.

How it's calculated

  • Mr (psi) = 1500 × CBR (AASHTO 1993)
  • Mr (psi) = 2555 × CBR^0.64 (MEPDG)
  • k (pci) = 28.69 × CBR^0.7788
  • log CBR = 2.465 − 1.12 log DCPI (ASTM D6951)

Results are calculated from the values you enter using standard formulas. Download the PDF to keep a record. For certified testing, design or construction, talk to our engineers.

Cite this tool

Kataria Engineering & Consultancy Services (2026). CBR → Mr & k-value [online calculator]. https://katariaengineering.com/tools/cbr-resilient-modulus-k-value.html